Zennio ZAS-AUDIO8B: 8-Zone KNX Amplifier Setup and Scene Programming
The Zennio ZAS-AUDIO8B is an 8-channel KNX amplifier (2x25W RMS per zone, 8 ohm) with 4 line-level RCA inputs, DIN rail mounted (8TE), 90-240VAC supply. All control — power, source, volume, bass, treble, mute, scene — is KNX-native, fully parameterised in ETS6.
ETS6 Parameterisation
Import from ETS Online Catalog (product number ZAA-AUD8Z). For each zone, configure in the Zone N tab:
Power on/off: DPT 1.001. Source selection: DPT 5.010 (values 1-4 corresponding to RCA inputs 1-4). Volume: DPT 5.001 (0-100%). Volume step: DPT 1.007 (increase/decrease pulse). Mute: DPT 1.001. Treble and bass: DPT 6.001 (signed byte, -7 to +7). Scene: DPT 18.001 (scene number 1-64).
Example GA assignment for zone 1: power = 5/0/1, source = 5/0/2, volume = 5/0/3, mute = 5/0/5. Replicate per zone (5/0/x, 5/1/x, etc.).
Scene Configuration
Each scene number (1-64) stores power state, source, and volume for all 8 zones simultaneously. Typical scenes: scene 1 = Evening (zones 1-3 on, source 1 'Streaming', 30% volume; zones 4-8 off), scene 2 = Party (all zones on, source 3 'Bluetooth', 60% volume), scene 3 = Night (only master bedroom zone 1, source 2 'Radio', 15% volume).
Trigger via DPT 18.001 on scene GA 0/0/10. The same GA connects to KNX HVAC 'all zones off' scene — one telegram turns off HVAC and audio simultaneously.
Speaker Wiring
Each zone: stereo pair output (L+ L- R+ R-). 8-ohm nominal speakers: direct connection, 2x1.5mm2 up to 12m cable run, 2x2.5mm2 up to 20m. Two 8-ohm speakers in parallel per zone = 4-ohm load (ZAS-AUDIO8B minimum). Three or more speakers parallel: use impedance-matching volume controls (100V line transformer for larger distributions).
Source Inputs
RCA rear inputs: Source 1 = NAS streaming (Volumio line out), Source 2 = TV audio out (optical-to-analog adapter), Source 3 = Bluetooth receiver analog out (Nobsound B10), Source 4 = doorbell station audio feed. Input impedance 22k ohm — compatible with all standard line-level sources.
IR Remote Per Zone
IR receiver input per zone (3.5mm jack, 12V IR eye supply). Zennio ZIR-AUDIO receiver mounted per zone near speakers. Supports NEC-protocol remote for local zone control. Disable IR in ETS6 for zones not requiring local control.
Need help with your KNX or DALI project?
Our certified engineers can discuss panel design, commissioning, integrations and project-specific edge cases. Free initial consultation.
Contact our engineers →